    A former coworker was abroad most of the time. Still, his power meter showed lots of usage during his absence. A tenant in the same house had used such a cord to leech power across the common laundry room.

    Now that coworker knew his way about electricity. So instead of the 220V between common and a phase, he rewired his washing machine socket to two different phases, aka 380V, and left for a week.

    When he came back, he saw a number of kitchen- and other appliances waiting for trash collection.

      • Treczoks@lemmy.world
        link
        fedilink
        arrow-up
        0
        ·
        6 days ago

        Absolutely normal here. Three phases, now 400 instead of 380V back then, 64A. Standard house connection.

        • FourWaveforms@lemm.ee
          link
          fedilink
          arrow-up
          0
          ·
          5 days ago

          In the States the new standard is 240V @ 200 amps, split phase. Most circuits are half of a phase (120V) but there are 240V circuits for load-heavy appliances like stoves and air conditioning. I’ve heard some people have an extra 240V socket in their kitchens just for tea kettles.

          • Treczoks@lemmy.world
            link
            fedilink
            arrow-up
            0
            ·
            5 days ago

            These-phase 400V is the standard house connection here in Europe. Wall sockets are 240V/16A (any phase to neutral), but we also have devices running on three phases, like the oven or the geyser in the kitchen.

              • Treczoks@lemmy.world
                link
                fedilink
                arrow-up
                0
                ·
                4 days ago

                Short answer: Yes.

                There are actually so-called “three phase combs” for the fuse panels: Sample Image. You put your fuses on a hat rail (in this case eight fuses, but those combs are available in different sizes), you stick that comb in from below and tighten up the screws. Then you connect the three phases to the connections on the left, or, in some fuse boxes, screw them right onto the bus bars.

  • A_Random_Idiot@lemmy.world
    link
    fedilink
    English
    arrow-up
    0
    ·
    6 days ago

    “this time of year” is 100% christmas.

    from people putting up lights, probably trying to run remote power to a box with an extension cord, or because they installed half their lights backward and need this to bridge between the two sets because they rather embrace the danger than redo all the work.

    • Sir_Simon_Spamalot@lemmy.world
      link
      fedilink
      arrow-up
      0
      ·
      6 days ago

      Except that sometimes, those idiots could take people down with them. That electrical fire might spread to another house, and the person getting electrocuted might not be the idiot.

      • dickalan@lemmy.world
        link
        fedilink
        arrow-up
        0
        ·
        6 days ago

        So you’re telling me it could take out their whole family line and any idiots that choose to engage with this idiot, this all sounds an absolute win

  • Steal Wool@lemm.ee
    link
    fedilink
    English
    arrow-up
    0
    ·
    7 days ago

    I sell so many of these around Xmas time, I just make them myself with scissors and electric tape.

  • rumba@lemmy.zip
    link
    fedilink
    English
    arrow-up
    0
    ·
    7 days ago

    Why not have the meters detect and control a disconnect. with all the solar generation around, someone’s gotta have a bad transfer switch somewhere.

    • MajorasMaskForever@lemmy.world
      link
      fedilink
      English
      arrow-up
      0
      ·
      7 days ago

      Reaction time

      In the US, using a cord like this will either be harmless or create effectively a dead short. Typical breakers will catch the latter but it will take tenths of a second for a breaker to react in which time the electricity could kill someone.

      Depending on circuit conditions a GFCI might intervene as well, they’re typically faster at reacting (needing a few milliseconds) but for a cable designed to handle full residential power, it’s still enough to kill a person in that small window of time

  • zymagoras777@lemm.ee
    link
    fedilink
    English
    arrow-up
    0
    ·
    7 days ago

    Most of eastern Europe do this and somehow linesmen don’t get killed. I’m not saying it’s the right thing to do but come on, guys, you have to adapt. If your government is shit.

    • kassiopaea@lemmy.blahaj.zone
      link
      fedilink
      arrow-up
      0
      ·
      7 days ago

      Well at that point all you need to do is cut a normal extension cord and strip the ends. Maybe add a switch or a button for extra safety.

  • ximtor@lemm.ee
    link
    fedilink
    arrow-up
    0
    ·
    edit-2
    7 days ago

    No idea how and why but my dad once had a cable like that in his workshop.

    Short story: we were having a party, bit drunk and wanted power for the bigger speakers, needed an extension, rummaged around and found this one. Of course didn’t check the ends, plugged it in and then thought “oh what a weird male adapter there, lets take it…bzzzzt”.

    Have a tiny burn scar on my hand now, luckily nothing else happened. The cable got dismantled afterwards, but I still don’t know why it was there in the first place, he is a pretty good handyman normally.

    • qjkxbmwvz@startrek.website
      link
      fedilink
      arrow-up
      0
      ·
      7 days ago

      If you lose power, you can use one of these cables to power your house (or at least, the part of your house on that phase).

      This is not how you should do this, but it can work. It is not a good idea (possibly illegal?).

      • kassiopaea@lemmy.blahaj.zone
        link
        fedilink
        arrow-up
        0
        ·
        7 days ago

        In my jurisdiction, backfeeding your house from a receptacle is very illegal. Transfer switches and interlock kits exist for a reason.

        For anyone wondering exactly why it’s a bad idea: Power from your generator can, if your house isn’t isolated from the grid, travel back into the utility lines and backward through the big transformer at the utility pole (so now it’s a few thousand volts again) and give an unsuspecting linesman a nasty surprise. People have died from this. It is a bad idea.

        • Taleya@aussie.zone
          link
          fedilink
          English
          arrow-up
          0
          ·
          7 days ago

          This is also why solar inverters in most countries MUST be able to ‘island’ (logically disconnect from grid) in order to tun a battery.

          We don’t have a battery yet, so our inverter shuts down on grid loss. Frustrating as hell when there’s an outage on a sunny day, but i get it.

        • MothmanLives@lemdro.id
          link
          fedilink
          English
          arrow-up
          0
          ·
          7 days ago

          Seems like the power companies should be responsible for either checking there is no back feeding or provide those things for everyone then. (I’m still not advocating for you back feeding your home)

          • InputZero@lemmy.world
            link
            fedilink
            arrow-up
            0
            ·
            7 days ago

            You’d have to constantly test. Just because a lines worker tested that the line is dead five seconds ago doesn’t mean some idiot just plugged one of these in.

            They can work, you just need to disconnect your house first then use it. It’s also a good way to burn your house down. If something on the same circuit as the generator pulls more current than the wires in the walls are designed to take, because there’s no breaker in the way anymore it can catch fire.

          • Sludgeyy@lemmy.world
            link
            fedilink
            arrow-up
            0
            ·
            7 days ago

            You can’t check for back feeding.

            Cable coming from house to pole has no power. Electrician goes to hook up wire. Homeowner puts on generator. Electrician gets electrocuted.

            Yes the testing and hooking up could be a small window of time but a fraction of a second after testing is all it takes.

  • N3Cr0@lemmy.world
    link
    fedilink
    arrow-up
    0
    ·
    7 days ago

    My granpa once assigned a master electrician to make an extension cord after he accidently cut the cable of his hedge trimmer. The electrician built him a male2male cord with the female part on the machine. My granpa almost got electrocuted. 🤦‍♂️

  • wjrii@lemmy.world
    link
    fedilink
    arrow-up
    0
    ·
    7 days ago

    I have heard there are ways to use these to back feed power from a generator into a house’s system, at least on one breaker, but by definition that bypasses the breaker panel, and the only safe way to use your generator for your house is with a proper cutover installed by an electrician. I can think of literally no other use for one of these cords, except maybe fixing your fuck up if you install Christmas lights backwards.

    So yeah, dumb, dumb idea.

    • Random_Character_A@lemmy.world
      link
      fedilink
      arrow-up
      0
      ·
      7 days ago

      There are voltage converters (230V<->120V) that have female connectors in both ends. So if DIY guys are playing with tech from other continents.

    • A_Union_of_Kobolds@lemmy.world
      link
      fedilink
      arrow-up
      0
      ·
      edit-2
      7 days ago

      This is all reasonably accurate. Source: electrician, who worked at a supply store for a while. I’ve had people ask how to make all kinds of stupid cords.

      If you don’t know what you’re doing, don’t fool with electricity

        • A_Union_of_Kobolds@lemmy.world
          link
          fedilink
          arrow-up
          0
          ·
          edit-2
          7 days ago

          Oh I know.

          I’ve talked to them.

          Don’t do it. If you haven’t actually worked with an electrician for at least two or.three years, just leave the repairs and shit jobs for people like me.

          If you can’t explain why the white wire is incorrectly called a neutral in single-phase systems, don’t touch it.

      • A_Union_of_Kobolds@lemmy.world
        link
        fedilink
        arrow-up
        0
        ·
        edit-2
        7 days ago

        This is the real issue and why you need a modern transfer switch. Lineman is working on the transformer on the pole, “it’s fine we cut it off upstream and I checked” and BOOM anyway

    • The_Hideous_Orgalorg@sh.itjust.works
      link
      fedilink
      arrow-up
      0
      ·
      7 days ago

      My friend’s house does this with their generator. There is a lockout on the breaker, and the main must be off to move it and open the one that feeds the back porch where they tie the generator in. Once the breakers are cycled, they can plug the generator into the outlet on the porch, and it runs there, sheltered from the weather. When the main power is working again, they turn off the generator, remove the cord, disable the breaker, toggle the lockout bar, and turn the main back on. The particular outlet on the porch is useless when using grid power because of this setup.

    • bluesheep@lemm.ee
      link
      fedilink
      arrow-up
      0
      ·
      7 days ago

      I’ve heard the Christmas lights one before too, but I never got it. How do (American) Christmas lights work that you’d need one of these cords?

      • ShawiniganHandshake@sh.itjust.works
        link
        fedilink
        arrow-up
        0
        ·
        7 days ago

        In North America, Christmas lights usually have a plug end and a socket end so you can connect multiple strings together in series.

        If you accidentally put the plug end at the top of the tree, it might be tempting to try to buy or make one of these cords so you don’t have to take the lights down and redo them.

        It is as dumb and lazy as it sounds.

        • bluesheep@lemm.ee
          link
          fedilink
          arrow-up
          0
          ·
          7 days ago

          So if I understand it correctly, if you were to use this “solution”, you’d leave live exposed prongs on one end of the lights, right?

          Cause that would make it even dumber than I had imagined lmao

          • wjrii@lemmy.world
            link
            fedilink
            arrow-up
            0
            ·
            7 days ago

            Yup. American Christmas lights basically ARE very thin extension cords with the bulbs (hopefully) wired in parallel. Back in the day they were pretty much all incandescent and in series, and a single burned out bulb meant everything went out and Junior got a joyous new holiday chore!

    • CoopaLoopa@lemmy.dbzer0.com
      link
      fedilink
      arrow-up
      0
      ·
      7 days ago

      Connecting this to two plugs on the same circuit won’t short anything unless one of the outlets is wired incorrectly.

      They’re used to backfeed power to your house from a generator during power outages. Technically not legal to use, but most people aren’t going to pay $1k for a proper transfer switch. They come with the caveat of ‘not to be operated by fuckwits’ since you can kill a linesman if you don’t flip your main breaker before using them.

    • Captain Aggravated@sh.itjust.works
      link
      fedilink
      English
      arrow-up
      0
      ·
      7 days ago

      Some genius won’t pay attention to the orientation of a christmas light display while he’s putting them up, he’ll go to plug them in, and they’ll be the wrong way, so he’ll want an “adapter.”

    • sugarfoot00@lemmy.ca
      link
      fedilink
      English
      arrow-up
      0
      ·
      7 days ago

      The only time I’ve ever seen one in use was a friend that had a shed that was powered with lights etc. He had an external plug box on the shed, and would use one of these to jumper from his extension cord to that external plug. It worked, but I shuddered when I saw it.

      • scrion@lemmy.world
        link
        fedilink
        arrow-up
        0
        ·
        7 days ago

        … and you could easily fix the whole situation by having the shed run a male extension cord out that could be plugged into the generator.

        It would also be infinitely more whimsical, since it’d make the shed look like a little appliance with its own chord. Or paint everything and call it a tail, the possibilities are endless.

        “Well, let me just plug in the shed real quick”

    • HereIAm@lemmy.world
      link
      fedilink
      arrow-up
      0
      ·
      7 days ago

      I will just regurgitate what I’ve heard. I think they are used in case power goes out and you have a generator. You need to disconnect from the power grid first, but it should then allow you to power tour house with the generator. It sounds more like a US thing.

      • jubilationtcornpone@sh.itjust.works
        link
        fedilink
        arrow-up
        0
        ·
        7 days ago

        Yes, this would technically work. Although, it would only power the hot leg the outlet is connected to which only feeds part of the house.

        It’s very dangerous for a variety of reasons. Especially if you forget to shut off the mains breaker. The transformer can backfeed power down the line at line voltages, creating a shock hazard for lineman or anyone else who might have contact with the line.

        • LH0ezVT@sh.itjust.works
          link
          fedilink
          arrow-up
          0
          ·
          7 days ago

          Wouldn’t any repair worker ground anything they work on first, or assume it is live? I am not even a proper electrician, but “short-circuited and grounded, or treat it as live” has been the rule forever.

          • originaltnavn@lemm.ee
            link
            fedilink
            arrow-up
            0
            ·
            7 days ago

            Not an electrician, but I would imagine the danger being if the technician checked the wire was off locally, started work and then the home generator starts feeding mid work.